Mi Home Double Light Switch
Quick Start Guide
The Double Light Switch is part of the MiHome home
automation range for the switching of mains power to lighting
up to 250W (50W for LEDs) per circuit. The product can be
controlled manually via the push button. Used with a MiHome
Gateway (MIHO001) registered to a MiHome account, it can
also be controlled remotely via the MiHome smartphone app
or through a browser.
In the Box:
Double light switch, Screw fittings, User guide
Compatibility
We recommend incandescent & halogen bulbs which are
250W max, or dimmable LED bulbs which are maximum 50W
in total andnot exceeding 6 bulbs per circuit.Not suitable for
fluorescent, non-dimmable LED and CFL bulbs or any light
requiring line drivers.
Installation
This device operates at UK mains voltage levels therefore we
advise installation from a competent, qualified person.It can
fit into a 25mm metal back-box or 35mm dry lining back-box,
but not into a 4 lug box. Please see "Installation Example"
section for wiring information.
Installation Notes
Can only be used in a two-way switching configuration with
a MiHome slave switch on circuit 1 (circuit 1 on MIHO009
labelled L, S1, L1).
Using any other switch as a slave will damage the Light
Switch.
The product requires power to circuit 1. If the power to both
circuits is removed while circuit 2 is switched on, and then
restored only to circuit 2, circuit 2 lamps will be lit whilst the
LED will be o. When power is restored to circuit 1 as well,
control for circuit 2 will also be restored, and the circuit 2
lamps will turn o.
Important
Applicable in England and Wales, where the installation of
this product falls under the scope of the Building Regulations
requirements for Part P, the installation must be carried out by
registered competent persons, and work should be designed
and installed, and inspected, tested and certificated in
accordance with BS 7671.
Applicable in Scotland, where the installation of this product
falls under the Building (Scotland) Act, a Warrant may be
required and advice should be sought from LABSS (Local
Authority Building Standards Scotland). We recommend that
a competent qualified person is used for all installations of
thisproduct.
Pairing with the MiHome Gateway
In order to control your Double Light Switch from the mobile
app or from a browser, it needs to first be paired with the
MiHomeGateway, as follows:
Pairing via the App on your Smartphone:
The Appmaybe downloaded free of charge from the Google
Play or iOS App Store.
1. Log into your MiHome account on the MiHome App.
2. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
3. Select "Add a new device" from menu and then choose "
Double Light Switch ", then choose Left or Right side as
required.
4. Follow onscreen pairing instructions,pressing the Double
Light Switch button when required for at least 8 seconds until
the LED begins to flash, and then release.
5. The LED will flash rapidly for a few seconds to indicate that
the Double Light Switch is being paired, the LED will go o
when this is complete.
6. The Double Light Switch should now be visible in the
device list (may take a few seconds depending on network
speed),refresh your browser if necessary.
7. Repeat steps 1-6 for the other switch side (left or right) as
required, always allow 1 minute between pairing devices or
dierent sides of the same device.
Pairing via a Browser
1. Log into your account atmihome4u.co.uk.
2. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
3. Select "Pair New Device", then click on the " Double Light
Switch " icon from the available options. Next click the "Pair
Device" button.
4. Follow onscreen pairing instructions,pressing the Double
Light Switch button when required forat least 8 seconds until
the LED begins to flash, and then release.
5. The LED will flash rapidly for a few seconds to indicate that
the Double Light Switch is being paired, the LED will go o
when this is complete.
6. The Double Light Switch should now be visible in the
device list (may take a few seconds depending on network
speed),refresh your browser if necessary.
7. Repeat steps 1-6 for the other switch side (left or right) as
required, always allow 1 minute between pairing devices or
dierentsides of the same device.
Operation Notes
1. A single press of the button while it is flashing will take it
out of pairing mode.
2. The Double Light Switch can be paired with up to 3
separate gateways. Further attempts to pair will overwrite
previous pairings.
Reset
The reset procedure will clear the memory of all paired
devices for the selected circuit (left or right).
1. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
2. To reset the Double Light Switch, press and hold the left or
right button as required for approximately 30 seconds, until
the LED has returned to steady ON. During these 30
seconds, the LED sequence will be, ON > Slow Flash > ON >
Quick Flash > ON.
Manual operation
A single short press of the button on the front of the housing
will toggle the Light Switch on or o. In normal use, the
buttons should not be pressed more than once every 3
seconds.


Produkt Specifikationer

Mærke: EnerGenie
Kategori: Smart hjem
Model: Mi Home Double Light Switch

Har du brug for hjælp?

Hvis du har brug for hjælp til EnerGenie Mi Home Double Light Switch stil et spørgsmål nedenfor, og andre brugere vil svare dig




Smart hjem EnerGenie Manualer

Smart hjem Manualer

Nyeste Smart hjem Manualer

Vimar

Vimar 20461.N Manual

15 December 2024
Vimar

Vimar 19537.M Manual

15 December 2024
Vimar

Vimar 14461.SL Manual

15 December 2024
Vimar

Vimar 14537 Manual

15 December 2024
Vimar

Vimar R21511.1.B Manual

15 December 2024
Vimar

Vimar R21511.1 Manual

15 December 2024
Vimar

Vimar 16849.B Manual

15 December 2024
Vimar

Vimar 19849 Manual

15 December 2024
Vimar

Vimar 20172.120.N Manual

15 December 2024