Frient Air Quality Sensor Manual

Frient Ikke kategoriseret Air Quality Sensor

Læs nedenfor 📖 manual på dansk for Frient Air Quality Sensor (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 23 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
eng
50 cm
150 cm
WALL
Fault nding & cleaning
In case of a bad or wireless weak signal,
change the location of the Air Quality
Sensor. Otherwise you can relocate your
gateway or strengthen the signal with a
smart plug.
If the search for a gateway has timed out, a
short press on the button will restart it.
Battery replacement
The device will blink twice every minute when
the battery is low.
CAUTION: Risk of explosion if batteries are
replaced by an incorrect type. Dispose of the
batteries in accordance with instructions.
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside
Open the casing of the Air Quality Sensor to
replace the batteries.
Replace the batteries respecting the
polarities.
Close the casing of the sensor.
Resetting
Resetting is needed if you want to connect
your Air Quality Sensor to another gateway or
if you need to perform a factory reset to avoid
abnormal behavior.
STEPS FOR RESETTING
1. Open the casing of the sensor.
2. Press and hold the round menu button
inside the device.
Mounting
1. Open the casing of the Air Quality Sensor
by pushing the switch and pulling the top
of the casing..
Placement
PLACE THE SENSOR
Indoors at a temperature between 0-50°C.
Inside the room, in which you want to
monitor VOC levels.
On a wall, where it is reachable for battery
replacement and maintenance.
Connecting
When the batteries are inserted, the Air
Quality Sensor will start searching (up to 15
minutes) for a Zigbee network to join.
Make sure that the Zigbee network is open
for joining devices and will accept the
sensor.
While the sensor is searching for a Zigbee
network to join, the LED ashes red.
Product description
The Air Quality Sensor monitors indoor air
quality through continuous detection of volatile
organic compound (VOC) levels.
The sensor provides information on the VOC
levels, so adverse health aects caused by
unhealthy indoor air can be prevented.
By monitoring indoor air quality, the Air Quality
Sensor helps you ensure that the air inside the
room is clean and healthy.
Version 1.2
INSTALLATION MANUAL
Air Quality Sensor
4. Make sure that the sensor has
joined a network before closing the casing.
3. Insert batteries respecting the polarities.
e.
b.
a.
c.
d.
f.
Disposal
Dispose the product and batteries properly at
the end of their lives. This is electronic waste
which should be recycled.
2. Use double-sided tape or screws to attach
the sensor on the wall. When the LED stops ashing, the sensor
has successfully joined the Zigbee network.
If the scanning has timed out, a short press
on the round menu button will restart it.
Precautions
Do not remove the product label as it
contains important information.
Be aware that electronics are sensitive
to static electricity, so aim to discharge
before touching, and avoid touching any
components inside the device.
Avoid placing the sensor close to radiators
or electromagnetic elds.
Do not paint the sensor.
3. While you are holding the button down, the
LED rst ashes once, then two times in a
row, and nally numerous times in a row.
4. Release the button while the LED is ashing
numerous times in a row.
5. After you release the button, the LED shows
one long ash, and the reset is completed.


Produkt Specifikationer

Mærke: Frient
Kategori: Ikke kategoriseret
Model: Air Quality Sensor

Har du brug for hjælp?

Hvis du har brug for hjælp til Frient Air Quality Sensor stil et spørgsmål nedenfor, og andre brugere vil svare dig