Busch-Jaeger 2CKA006200A0048 Manual

Busch-Jaeger Smart hjem 2CKA006200A0048

Læs nedenfor 📖 manual på dansk for Busch-Jaeger 2CKA006200A0048 (2 sider) i kategorien Smart hjem. Denne guide var nyttig for 19 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Pos: 2 /BJE/Faltblat t 35x42/FB-Köpfe in Anlei tungen/6212/X.X, SDA.F-X.X.X - WL @ 50\mod_146616 7788906_0.doc x @ 673027 @ @ 1
6212/1.1-WL
6212/2.1-WL
SDA-F-1.1.1-WL
SDA-F-2.1.1-WL
2CKA000073B8970 / 23.09.2016
DE
EN
ES
IT
FR
www.busch-
jaeger.de/freeathome
www.abb.com/freeathome
=== Ende der Liste für Textmarke Titel ===
Pos: 4 / BJE/Faltblatt 35x42/FreeAThome/6212 / SDA-F -- Sensor/Dimmaktor/6212/X.X, SDA-F-X.X.X -- Sensor/Dimmaktor - WL @ 50\mod_1466167917075_1.doc x @ 673087 @ 1222222222 @ 1
Deutsch
Sensor/Dimmaktor 1/1-fach; 2/1-fach, wireless
WARNUNG
Bei direktem oder indirektem Kontakt mit spannungs-
führenden Teilen kommt es zu einer gefährlichen
Körperdurchströmung. Elektrischer Schock,
Verbrennungen oder der Tod können die Folge sein. Bei
unsachgemäß ausgeführten Arbeiten an
spannungsführenden Teilen besteht Brandgefahr.
Vor Montage und Demontage Netzspannung
freischalten!
Arbeiten am 230 V-Netz nur von Fachpersonal
ausführen lassen.
Ŷ Montageanleitung sorgfältig lesen und aufbewahren.
Ŷ Weitere Benutzerinformationen unter www.busch-
jaeger.de/freeathome | www.abb.de/freeathome oder durch
Scannen des QR-Codes in dieser Anleitung.
Ŷ Informationen zur Systemeinbindung siehe Systemhandbuch
(www.busch-jaeger.de/freeathome | www.abb.de/freeathome).
Bestimmungsgemäßer Gebrauch
Der Dimmsensor bildet eine Einheit mit dem Universal-Dimmaktor.
Dieser ist für die Ansteuerung und das Dimmen verschiedener Lasten
bestimmt. Die Geräte sind entsprechend vorkonfiguriert. Nach
Anschluss der Last kann diese direkt geschaltet/gedimmt werden
(2/1-fach, über linke Wippe).
Ŷ Ausführliche Informationen zum Funktionsumfang siehe
Technisches Handbuch (siehe QR-Code in dieser Anleitung).
Konformitätserklärung
Hiermit erklärt Busch-Jaeger Elektro, dass der Funkanlagentyp
6212/1.1-WL, 6212/2.1-WL, SDA-F-1.1.1-WL und SDA-F-2.1.1-WL
der Richtlinie 2014/53/EU entspricht.
Der vollständige Text der EU-Konformitätserklärung ist unter der
folgenden Internetadresse verfügbar:
6212/1.1-WL www.busch-jaeger-katalog.de/6200-0-
0047,artikel.html
SDA-F-1.1.1-WL www.busch-jaeger-catalogue.com/6200-0-
0077,artikel.html
Technische Daten
Betriebsspannung 230 V AC, 50/60 Hz
Anschluss L, N (optional), Ein- und Ausgänge
potential gebunden
Schraubklemme:
2 x 2,5 mm² starr;
2 x 1,5 mm² flexibel
Spreize mit Berührschutz und Rückstellung
(optional entfernbar)
Übertragungsprotokoll free@home wireless
Übertragungsfrequenz 2,400 … 2,483 GHz
Maximale Sendeleistung
WL (wireless)
< 15 dBm
Leistungsaufnahme < 1 W
Nennlast Konventionell:
Ŷ 3-Draht 10 - 180 W
Ŷ 2-Draht 20 - 180 W
LEDi/CFLi:
Ŷ 2-Draht und 3-Draht: typ. 2 - 80 W
Einschränkungen bei geringeren
Lasten im 2-Drahtbetrieb sind möglich!
Schutzart IP20
Umgebungstemperatur -5 °C … +45 °C
Lagertemperatur -20 °C … +70 °C
Montage
Hinweis
Sender und Empfänger kommunizieren über Funk. Die Reichweite ist
von den baulichen Gegebenheiten abhängig. Wände oder Decken,
insbesondere mit Stahlarmierungen oder Metallverkleidungen,
schränken die Reichweite ein. Der Abstand der Komponenten
zueinander und zu fremden Sendegeräten, die ebenfalls
hochfrequente Signale abstrahlen (z.B. Computer, Audio- und
Videoanlagen) sollte mindestens 1 m betragen.
Einbau nur in Unterputzdosen, die sich in trockenen Innenräumen
befinden. Dabei die geltenden Vorschriften beachten. Ident-Label
abziehen und in die Liste einkleben (bei System Access Point).
Ŷ Abdeckrahmen und Abdeckungen separat bestellen.
Ŷ Die möglichen Schalterserien dem elektronischen Katalog
entnehmen (www.busch-jaeger-katalog.de).
Anschluss
Ŷ Der Betrieb an Trenntransformatornetzen mit einer
Anschlussleistung 10 kVA ist nicht zulässig!
Ŷ Maximal zulässige Anschlussleistung: 100 % = -5 °C…45 °C
Betriebstemperatur (siehe Derating-Kurve [1]: % = Nennleistung;
°C = Umgebungstemperatur)
Ŷ Auf korrekte Verdrahtung achten.
Lastarten
Ŷ Optimiert für RetrofitǦ ǦLED Leuchtmittel (LEDi)
Ŷ Niedervolt Halogenlampen mit konventionellen Transformatoren
nach IEC 61558.
Weitere Informationen: siehe Dimmer-Konfigurator
Inbetriebnahme
Ein nicht angelerntes Gerät befindet sich bei jeder Bestromung für
30 Minuten im Anlernmodus und kann an das System angemeldet
werden.
Die Anmeldung erfolgt über die Inbetriebnahmeoberfläche des
System Access Point.
Ein schon angemeldetes Gerät muss zurückgesetzt werden,
damit es erneut in den Anlernmodus versetzt wird.
Vorgang:
1. Gerät spannungsfrei schalten
2. Spannung einschalten und gleichzeitig Taste (links unten) mind.
15 Sek. gedrückt halten, bis LED zu blinken aufhört
Das Gerät muss zur Ausführung zusätzlicher Funktionen parametriert
werden.
Ŷ Ausführliche Informationen zu Inbetriebnahme und
Parametrierung befinden sich im Technischen Handbuch und in
der Onlinehilfe des System Access Point (www.busch-
jaeger.de/freeathome | www.abb.de/freeathome).
Ŷ Das Firmware-Update erfolgt über den System Access Point.
Weitere Produktmerkmale
Ŷ LEDs als Orientierungslicht/Statusanzeige
Ŷ Austauschbare Abdeckungen mit entsprechenden Symbolen
Service
Busch-Jaeger Elektro GmbH - Ein Unternehmen der ABB Gruppe,
Freisenbergstraße 2, D-58513 Lüdenscheid,
Tel.: +49 2351 956-1600; D: 0800 3733 28 4
www.BUSCH-JAEGER.de
Pos: 5 /BJE/Faltblat t 35x42/FreeAThome/621 2 / SDA-F -- Sensor/Di mmaktor/6212/X.X, SD A-F-X.X.X -- Sensor/Di mmaktor - WL @ 50\mod_14661679170 75_15.docx @ 673090 @ 122222 2222 @ 1
English
Sensor/dimming actuator, 1/1gang; 2/1gang,
wireless
WARNING
Dangerous currents flow through the body when coming
into direct or indirect contact with live components. This
can result in electric shock, burns or even death. Work
improperly carried out on current-carrying parts can cause
fires.
Disconnect the mains power supply prior to installation
and disassembly!
Permit work on the 230 V supply system to be
performed only by specialist staff.
Ŷ Please read the mounting instructions carefully and keep them for
future use.
Ŷ Additional user information is available at
www.abb.com/freeathome or by scanning the QR code in this
instruction manual.
Ŷ For information on system integration please see the system
manual (www.abb.com/freeathome).
Intended use
The dimming sensor and the universal dimming actuator form a
single unit. It is intended for the activation and dimming of various
loads. The devices have been pre-programmed accordingly. After the
load is connected, it can be directly switched/dimmed (2/1gang, via
the left rocker).
Ŷ For detailed information about the range of functions see the
technical reference manual (see QR code in this instruction
manual).
Declaration of conformity
Busch-Jaeger Elektro herewith declares, that radio system type
6212/1.1-WL, 6212/2.1-WL, SDA-F-1.1.1-WL andSDA-F-2.1.1-WL
conforms to directive 2014/53/EU.
The complete text of the EU declaration of conformity is available at
the following Internet address:
6212/1.1-WL www.busch-jaeger-katalog.de/6200-0-
0047,artikel.html
SDA-F-1.1.1-WL www.busch-jaeger-catalogue.com/6200-0-
0077,artikel.html
Technical data
Operating voltage 230 V AC, 50/60 Hz
Connection L, N (option), inputs and outputs non-
floating
Screw-type terminal:
2 x 2.5 mm² rigid;
2 x 1.5 mm² flexible
Claw With protective cover and reset
(removable)
Transmission protocol free@home wireless
Transmission frequency 2.400 - 2.483 GHz
Maximum transmission
power WL (wireless)
< 15 dBm
Power consumption < 1 W
Nominal load Conventional:
Ŷ 3-wire 10 - 180 W
Ŷ 2-wire 20 - 180 W
LEDi/CFLi:
Ŷ 2-wire and 3-wire: typ. 2 - 80 W
Limitations at reduced loads in 2-wire
operation are possible!
Protection IP20
Ambient temperature -5°C - +45°C
Storage temperature -20°C - +70°C
Mounting
NOTE
Transmitter and receiver communicate via radio control. The
transmission range depends on the structural conditions. Walls and
ceilings, especially steel reinforcements or metal claddings, reduce
the transmission range. The distance of components to each other
and to other transmitters that also emit high-frequency signals (e.g.
computers, audio and video systems) should be at least 1 m.
They may only be installed in dry interior rooms in flush-mounted
boxes. Observe the currently valid regulations. Remove the
identification label and glue it into the list (at System Access Point).
Ŷ Please order the cover frame and covers separately.
Ŷ Please see the electronic catalogue for the possible switch ranges
(www.busch-jaeger-catalogue.com).
Connection
Ŷ Operation with isolating transformer networks with a connected
load of 10 kVA is not admissible!
Ŷ Maximum admissible connected load: 100% = -5°C to 45°C
operating temperature (see derating curve [1]:
% = nominal power; °C = ambient temperature)
Ŷ Observe correct wiring.
Types of load
Ŷ Optimised for retrofit LED lamps (LEDi)
Ŷ Low-voltage halogen lamps with conventional transformers
according to IEC 61558.
For additional information: see dimmer configurator
Commissioning
When energized, every non-programmed device is in programming
mode for 30 minutes and can be logged into the system.
The login is carried out via the commissioning interface of the System
Access Point.
A device that has already been logged in must be reset to enable
it to be set again into programming mode.
Procedure:
1. Disconnect the device from power.
2. Switch on the power and simultaneously keep the button
(bottom left) pressed for at least 15 seconds, until the LED stops
flashing.
The device must be parameterized for the use of additional functions.
Ŷ Detailed information about commissioning and parameterization is
available in the technical reference manual and the online help of
the System Access Point (www.abb.com/freeathome).
Ŷ The firmware update is carried out via the System Access Point.
Additional product features
Ŷ LEDs as light for orientation / status indication
Ŷ Exchangeable covers with the corresponding icons
Service
Busch-Jaeger Elektro GmbH - A member of the ABB Group,
Freisenbergstraße 2, D-58513 Lüdenscheid, Germany,
Tel.: +49 2351 956-1600;
www.BUSCH-JAEGER.com
Pos: 6 /sy stem modules/++++++++++++++ page break +++++++++++++++ @ 41\mod_1422789416992_0.doc x @ 333485 @ @ 1
Busch ABB home-/ -free
@
®
LEDi
230 V AC
CFLi
230 V AC
L
N
10 A
LN
1
1 3
2 4
L
N
10 A
LN
1
R,L ,C
230 V


Produkt Specifikationer

Mærke: Busch-Jaeger
Kategori: Smart hjem
Model: 2CKA006200A0048

Har du brug for hjælp?

Hvis du har brug for hjælp til Busch-Jaeger 2CKA006200A0048 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Smart hjem Busch-Jaeger Manualer

Smart hjem Manualer

Nyeste Smart hjem Manualer