Busch-Jaeger 6252/0.4-101 Manual

Busch-Jaeger Smart hjem 6252/0.4-101

Læs nedenfor 📖 manual på dansk for Busch-Jaeger 6252/0.4-101 (2 sider) i kategorien Smart hjem. Denne guide var nyttig for 17 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
L N
A B C D
LL L L
1
AB C D
1
Bus
L1
N
L2
L3
+
-
A B C D
3 x 10 A )*
Bus
L1
N
+
-
A B C D
10 A
Bus
L1
N
+
-
A B C D
10 A
LEDi
230 V AC
CFLi
230 V AC
230 V AC
i
Pos: 2 /Faltbl att 35x42/00_FB- Kopf/FB-Köpfe in Anleitungen/ 6252, DA-M-0.4.2 @ 44\mod_1442232048132_0.doc x @ 378727 @ @ 1
6252/0.4-101
DA-M-0.4.2
0073-1-8802 / 2CKA00073B8802 / 08.04.2016
www.busch-jaeger.de/freeathome
www.abb.com/freeathome
== Ende der Liste für Textmarke Tit el ===
Pos: 4 / Falt blatt 35x42/ FreeAThome/6252 / DA-M-0.4 -- REG-Dimmer/6252-0.4-101 @ 44\mod_14 46827984562_1. docx @ 403060 @ 12222222 @ 1
Deutsch
Dimmaktor 4-fach, REG
WARNUNG
Bei direktem oder indirektem Kontakt mit spannungs-
führenden Teilen kommt es zu einer gefährlichen
Körperdurchströmung. Elektrischer Schock,
Verbrennungen oder der Tod können die Folge sein.
Vor Montage oder Demontage Netzspannung
freischalten!
Arbeiten am 230 V-Netz nur von Fachpersonal
ausführen lassen.
Montageanleitung sorgfältig lesen und aufbewahren.
Weitere Benutzerinformationen unter www.busch-
jaeger.de/freeathome | www.abb.de/freeathome oder durch
Scannen des QR-Codes.
Informationen zur Systemeinbindung siehe Systemhandbuch
(www.busch-jaeger.de/freeathome | www.abb.de/freeathome).
Bestimmungsgemäßer Gebrauch
Der 4-fach Universal-Dimmaktor ist für die Ansteuerung und das
Dimmen verschiedener Lasten bestimmt.
Ausführliche Informationen zum Funktionsumfang siehe
Technisches Handbuch (siehe QR-Code).
Technische Daten
Stromversorgung 24 V DC (erfolgt über Buslinie)
Busteilnehmer 1 (12 mA)
Anschluss Busanschlussklemme: 0,4 … 0,8 mm
Leitungstyp: J-Y(St)Y, 2 x 2 x 0,8 mm
Abisolierung: 6 … 7 mm
Netzanschluss 230 V AC, 50 / 60 Hz
Schraubklemmen: 1 … 6 mm
2
Nennlast 1 x 40 … 1260 W/VA
2 x 20 … 630 W/VA
4 x 10 … 315 W/VA
LEDi und CFLi:
typ. 1 x 8 … 160 W/VA
typ. 2 x 4 … 120 W/VA
typ. 4 x 2 … 80 W/VA
Schutzart IP20
Umgebungstemperatur -5 °C … +45 °C
Lagertemperatur -20 °C … +70 °C
Lastarten
Optimiert für RetrofitLEDLeuchtmittel
(LEDi).
Siehe auch Busch-Dimmer® Tool
Montage
Das Gerät nur auf Hutschienen nach DIN EN 60715 installieren.
Identlabel abziehen und in die Liste einkleben (bei System
Access Point).
Anschluss
Der Betrieb an Trenntransformatornetzen mit einer
Anschlussleistung ≤ 10 kVA ist nicht zulässig!
Maximal zulässige Anschlussleistung: 100 % = -5 °C 45 °C
Betriebstemperatur (siehe Deratingkurve [1]: % = Nennleistung;
°C = Umgebungstemperatur)
Beim Parallelschalten von Kanälen müssen diese an der gleichen
Phase angeschlossen sein (siehe *). Bei unterschiedlichen
Phasen wird der Dimmer beim Parallelschalten zerstört. Allpolige
Fehlerstromschutzschalter verwenden!
Kanalbündelung führt nicht zu Multiplikation der Kanallast
(max. 160 W/VA für LEDi / CFLi).
Hinweis
A
u
f
korrekte Polarität achten.
Bei konventionellen Trafos ~20 % Trafoverluste berücksichtigen.
Bedienung
[A-D] Ein Kanal je Taster (Kanalbündelung möglich);
Mit Memory-Funktion!
Kurzer Tastendruck: an/aus
Langer Tastendruck: dimmen
[1] Geräteidentifikation während der Inbetriebnahme
Inbetriebnahme
Das an die Buslinie angeschlossene Gerät wird nach einigen
Sekunden automatisch vom System erkannt. Das Gerät muss zur
Ausführung der Funktionen parametriert werden.
Im Auslieferungszustand besitzt der Dimmer je 4 einzeln
vorprogrammierte Kanäle. Eine Gruppenbildung zur Lasterhöhung ist
bei der Inbetriebnahme vorzunehmen. Der Dimmer führt bei
Inbetriebnahme einen automatischen Lasttest durch. Bei
Inbetriebnahme ohne Last, werden die Kanäle/Gruppen nicht
erkannt.
Inbetriebnahme und Parametrierung erfolgen über den System
Access Point.
Ausführliche Informationen zu Inbetriebnahme und
Parametrierung befinden sich im Technischen Handbuch (siehe
QR-Code) und in der Online-Hilfe des System Access Point
(www.busch-jaeger.de/freeathome | www.abb.de/freeathome).
Firmware-Update erfolgt über den System Access Point.
Service
Busch Ein Unternehmen der ABB Gruppe, Jaeger Elektro GmbH
Freisenbergstraße 2, D-58513 Lüdenscheid,
Tel. D+A: +49 2351 956-1600; CH: +41 58 586 06 53;
D: 0800 3733 28 4
www.BUSCH-JAEGER.de
Pos: 5 / Falt blatt 35x42/ FreeAThome/6252 / DA-M-0.4 -- REG-Dimmer/6252-0.4-101 @ 44\mod_14 46827984562_15. docx @ 403061 @ 12222222 @ 1
English
Dimming actuator, 4gang, MDRC
WARNING
Dangerous currents flow through the body when coming
into direct or indirect contact with live components. This
can result in electric shock, burns or even death.
Disconnect the mains power supply prior to installation
or disassembly!
Permit work on the 230 V supply system to be
performed only by specialist staff.
Please read the mounting instructions carefully and keep them for
future use.
Additional user information is available at
www.abb.com/freeathome or by scanning the QR code.
For information on system integration please see the system
manual (www.abb.com/freeathome).
Intended use
The 4gang universal dimming actuator is intended for the activation
and dimming of various loads.
For detailed information about the range of functions see the
technical reference manual (see QR code).
Technical data
Power Supply 24 V DC (via bus line)
Bus subscribers 1 (12 mA)
Connection Bus connection terminal: 0.4 - 0.8 mm
Line type: J-Y(St)Y, 2 x 2 x 0.8 mm
Wire stripping: 6 - 7 mm
Mains supply 230 V AC, 50/60 Hz
Screw-type terminals, 1 - 6 mm
2
Nominal load 1 x 40 - 1260 W/VA
2 x 20 - 630 W/VA
4 x 10 - 315 W/VA
LEDi and CFLi:
typ. 1 x 8 - 160 W/VA;
typ. 2 x 4 - 120 W/VA;
typ. 4 x 2 - 80 W/VA;
Protection type IP20
Ambient temperature -5°C - +45°C
Storage temperature -20°C - +70°C
Types of load
Optimised for retrofit LED lamps
(LEDi).
See also Busch-Dimmer® tool
Mounting
Install the device only on mounting rails according to DIN EN 60715.
Remove the identification label and glue it into the list (at System
Access Point).
Connection
Operation with isolating transformer networks with a connected
load of ≤ 10 kVA is not admissible!
Maximum admissible connected load: 100% = -5°C to 45°C
operating temperature (see derating curve [1]: % = nominal
power; °C = ambient temperature)
For parallel switching of channels, these must be connected to
the same phase (see *). In case of different phases, the dimmer
will be destroyed during parallel switching. Use all-pole earth-
leakage circuit breakers!
Bundling of channels does not lead to multiplication of channel
loads (max. 160 W/VA for LEDi/CFLi)
NOTE
Observe correct polarity.
In the case of conventional transformers, take ~20% transformer
losses into consideration.
Operation
[A-D] One channel per push-button (bundling of channels
possible);
With memory function!
Brief press of the button: on/off
Long press of the button: dimming
[1] Device identification during commissioning
Commissioning
The device connected to the bus line is automatically recognized by
the system after a few seconds. The device must be parameterized
for the use of the functions.
At the point of delivery the dimmer has 4 individual pre-programmed
channels. Group formation for increasing of loads is to be carried out
during commissioning. The dimmer carries out an automatic load test
during commissioning. The channels/groups will not be recognized
when commissioning without load.
Commissioning and parameterization is carried out via the
System Access Point.
Detailed information about commissioning and parameterization
is available in the technical reference manual (see QR code) and
the online help of the System Access Point
(www.abb.com/freeathome).
Firmware update is carried out via the System Access Point.
Service
Busch-Jaeger Elektro GmbH - A member of the ABB Group,
Freisenbergstraße 2, D-58513 Lüdenscheid, Germany,
Tel.: +49 2351 956-1600
www.BUSCH-JAEGER.com
Pos: 6 / Falt blatt 35x42/ FreeAThome/6252 / DA-M-0.4 -- REG-Dimmer/6252-0.4-101 @ 44\mod_14 46827984562_551 43.docx @ 403062 @ 12222222 @ 1
Espanõl
Actuador de atenuación de 4 elementos, REG
ADVERTENCIA
En caso de entrar en contacto, directa o indirectamente,
con componentes por los que circule una corriente
eléctrica, se puede sufrir una descarga eléctrica peligrosa,
cuyo resultado puede ser choque eléctrico, quemaduras o,
incluso, la muerte.
¡Desconecte la tensión de red antes de proceder al
montaje o desmontaje!
Encargue los trabajos en la red eléctrica de 230 V solo
al personal técnico competente.
Lea detenidamente y guarde en lugar seguro el manual de
montaje.
Más información para usuarios en www.abb.com/freeathome o
escaneando el código QR.
Para conocer la información sobre la integración en el sistema,
consulte el manual del sistema (www.abb.com/freeathome).
Uso conforme al fin previsto
El actuador universal regulador de 4 elementos está previsto para el
control y la regulación de distintas cargas.
Si desea información más detallada sobre las funciones, consulte
el manual técnico (véase el código QR).
Datos técnicos
Alimentación de
corriente 24 V c.c. (a través de línea de bus)
Participantes de bus 1 (12 mA)
Conexión Borne de conexión de bus:
0,4 … 0,8 mm
Tipo de cable: J-Y(St)Y, 2 x 2 x 0,8 mm
Pelado del cable: 6 … 7 mm
Conexión a la red 230 V c.a., 50 / 60 Hz
Bornes roscados, 1 ... 6 mm2
Carga nominal 1 x 40 … 1260 W/VA
2 x 20 … 630 W/VA
4 x 10 … 315 W/VA
LEDi y CFLi:
norm. 1 x 8 … 160 W/VA
norm. 2 x 4 … 120 W/VA
norm. 4 x 2 … 80 W/VA
Grado de protección IP20
Temperatura ambiente -5 °C … +45 °C
Temperatura de
almacenamiento -20 °C … +70 °C
Tipos de carga
Optimizado para lámparas LED Retrofit
(LEDi).
Véase también Busch-Dimmer® Tool
Montaje
Instale el aparato sobre carriles DIN según la norma EN 60715.
Retire la etiqueta de identificación y péguela en la lista (con
System Access Point).
Conexión
No se permite el funcionamiento con redes de transformadores
aislantes con una potencia conectada ≤10 kVA.
Potencia de conexión máxima admisible:
100 % = -5 °C…45 °C de la temperatura de servicio (véase la
curva de reducción [1]: % = potencia nominal;
°C = temperatura ambiente).
Al conectar los canales en paralelo, estos deberán conectarse en
la misma fase (véase *). Si se conectan en fases diferentes, el
regulador de luz se destruirá al conectarse en paralelo. Utilice
diferenciales multipolares.
La concentración de los canales no conduce a la multiplicación
de la carga del canal (máx. 160 W/VA para LEDi / CFLi).
Nota
Preste atención a la polaridad correcta.
Con los transformadores convencionales, téngase en cuenta un
~20 % de pérdidas en el transformador.
Manejo
[A-D] Un canal por tecla (posibilidad de concentración de
canales);
con función de memoria.
Pulsación breve: encender/apagar
Pulsación larga: regular
[1] Identificación de los aparatos durante la puesta en servicio
Puesta en marcha
El sistema reconoce, automáticamente tras unos segundos, al
aparato que se conecta a la línea de bus. El aparato se debe
parametrizar para realizar las funciones adicionales.
En el estado de entrega el actuador de atenuación cuenta con 4
canales preprogramados. En la puesta en servicio se realiza la
agrupación de los canales para aumentar la carga. El regulador de
luz ejecuta una comprobación automática de la carga durante la
puesta en servicio. Durante la puesta en servicio sin carga no se
reconocen los canales ni los grupos.
La puesta en servicio y la parametrización se realizan a través
del System Access Point.
Podrá encontrar información detallada sobre la puesta en servicio
y sobre la parametrización en el manual técnico (véase el código
QR) y en la ayuda online del System Access Point.
(www.abb.com/freeathome)
La actualización del firmware se realiza a través del System
Access Point.
Servicio postventa
BuschJaeger Elektro GmbH Una empresa del Grupo ABB,
Freisenbergstraße 2, D-58513 Lüdenscheid,
Tel.: +34 902 11 15 11
www.BUSCH-JAEGER.com
Pos: 10 /Sys temmodul e/++++++++++++++ Seitenumbruch +++++++++++++++ @ 41\mod_1422789416992_0.docx @ 33348 5 @ @ 1
=== Ende der Liste für Textmarke Inha lt ===
Pos: 12 /Faltbl att 35x42/00_FB-Kopf/FB-Köpfe in Anleitungen/ 6252, DA-M-0.4.2 @ 44\mod_1442232048132_0.doc x @ 378727 @ @ 1
Busch ABB home-/ -free
@
®


Produkt Specifikationer

Mærke: Busch-Jaeger
Kategori: Smart hjem
Model: 6252/0.4-101

Har du brug for hjælp?

Hvis du har brug for hjælp til Busch-Jaeger 6252/0.4-101 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Smart hjem Busch-Jaeger Manualer

Smart hjem Manualer

Nyeste Smart hjem Manualer